Transformer Calc NEC

Rizvan Adzhoian

$0.99 In-app purchases
Open on Apple

About this app

NEC transformer overcurrent protection calculator for electricians, apprentices, and electrical engineers. Size primary and secondary OCPD per NEC Table 450.3(B), calculate full-load amps (FLA), and select conductors from Table 310.16 - all per NEC 2023 (NFPA 70). Works 100% offline on the job site. Whether you're sizing overcurrent protection for a 75 kVA, 480-to-208V three-phase transformer, or checking if primary-only protection requires 125% or 300%, this calculator gives you accurate NEC-compliant results in seconds. Use it as your go-to transformer protection reference - from kVA rating to OCPD and conductor selection. TRANSFORMER CALCULATOR FEATURES: - Primary overcurrent protection per NEC 450.3(B) - 125%/167%/250%/300% rules - Secondary overcurrent protection per NEC 450.3(B) - 125%/167%/250% rules - Primary-only and primary+secondary protection methods - Full-load ampere (FLA) calculation: single-phase and three-phase - Next-standard-size-up applied only where Note 1 permits (125% cells); 167%/250%/300% treated as ceilings - All standard OCPD ratings per NEC 240.6(A), including fuse-only ratings 1, 3, 6, 10, 601 for small transformers - Conductor sizing from NEC Table 310.16 (75°C column, printed code values) - Copper and aluminum conductor support - 40 standard kVA ratings: 0.05–500 kVA single-phase, 3–2500 kVA three-phase - 7 voltage presets: 120V, 208V, 240V, 277V, 460V, 480V, 600V - Single-phase and three-phase support - NEC article references for every calculation result NEC REFERENCES INCLUDED: - NEC Table 450.3(B) - Transformer overcurrent protection (600V or less) - NEC 450.3(B) Note 1 - Next-size-up rule for primary-only protection - NEC 240.6(A) - Standard overcurrent device ratings - NEC Table 310.16 - Conductor ampacity at 75°C PROTECTION METHOD RULES (printed Table 450.3(B)): - Primary Only, 9A or more: 125% maximum — next standard size up permitted (Note 1) - Primary Only, 2–9A: 167% maximum — ceiling, no round up - Primary Only, under 2A: 300% maximum — ceiling, no round up - Primary + Secondary: primary 250% maximum (ceiling); secondary 125% (Note 1) for 9A or more, 167% ceiling under 9A CALCULATION RESULTS INCLUDE: - Primary full-load amps (FLA) with formula - Secondary full-load amps (FLA) with formula - Primary OCPD size (standard rating per NEC 240.6(A)) - Secondary OCPD size when applicable - Primary and secondary conductor sizes with ampacity - Applicable NEC percentage rules and references - Protection method notes and explanations PRO FEATURES (one-time purchase): - No ads - clean interface for professionals - Save transformer calculation history with labels - Export calculations as PDF reports for permits and records - Dark theme support HOW THE TRANSFORMER CALCULATOR WORKS: 1. Select phase type (single-phase or three-phase) 2. Choose kVA rating from standard sizes 3. Select primary and secondary voltage 4. Choose protection method (primary only or primary + secondary) 5. Select conductor material (copper or aluminum) 6. Get OCPD sizes, conductor recommendations, and NEC references instantly BUILT FOR ELECTRICIANS ON THE JOB SITE: This transformer calculator is designed by electricians, for electricians. Enter your transformer parameters, get the correct OCPD size and conductor recommendation instantly - no complicated menus or unnecessary features. One-hand operation, instant results. PERFECT FOR: - Licensed electricians sizing transformer protection daily - Electrical apprentices studying for journeyman exams - Electrical engineers and designers - Electrical contractors bidding jobs - NEC code exam preparation - Journeyman and master electrician exam study OFFLINE & PRIVACY: - Works 100% offline - no internet needed on the job site - No account required - No data collection - your calculations stay on your device Simplify your transformer protection sizing on the job site.

Latest release

What’s New

Version 1.0.10 Jul 10, 2026

What's new: • Secondary conductor sizing now follows NEC 240.21(C): the conductor is sized so the secondary breaker never exceeds its ampacity — no next-size-up on the secondary (e.g. a 75 kVA 208V secondary is 350 kcmil, not 300) • Large transformers that exceed a single conductor now show parallel sets per NEC 310.10(H), e.g. "2 × 600 kcmil", instead of a blank result • More precise three-phase current (exact √3) Thanks for using ElecTools! Send feedback to support@tradetools.dev.

Audience growth

Ratings growth

Steady
7-day gain +0
Ratings / day 0.0
30-day gain +0
US rating-count history
0 ratings
0 Oct 16, 2026 · 0 ratings Oct 16, 2026

Baseline captured. Growth appears after the crawler observes a changed rating count.

Momentum comes from crawler snapshots for the tracked storefront. “Viral growth signal” means unusually fast recent rating gains; it is an indicator, not download data.

Price tracking

Price intelligence

1 captured event
Current $0.99
Historical low USD 0.99
Paid → free 0×
Price history
Current $0.99
$0.99 $0.50 Free Oct 16, 2026 · $0.99 Oct 16, 2026

First snapshot captured. The trend line starts after the next crawler price observation.

  1. First observed Oct 16, 2026 · 4:59 PM $0.99

Screenshots

Transformer Calc NEC iPhone screenshotTransformer Calc NEC iPhone screenshotTransformer Calc NEC iPhone screenshotTransformer Calc NEC iPhone screenshot Transformer Calc NEC iPad screenshotTransformer Calc NEC iPad screenshotTransformer Calc NEC iPad screenshotTransformer Calc NEC iPad screenshot